INDUCTION HEATING CABLES


I²r specializes in comprehensive services for all designs of water-cooled power cables. Our services include repair, rebuild, replacement and supply of power cables for new applications. By providing our customers with several options and recommendations in sizing, new and redesigned terminals and thermal and abrasion concerns, they become an integral part of the decision making process. Our familiarity with designs from around the world allows us to optimize all Original Equipment Manufacturer (O.E.M.) cable designs and specifications. Most cables can be improved for better service, greater line loss efficiency, better thermal protection and abrasion resistance regardless of your systems’ heating process.

I²r is not limited to repair and replacement services. With over 40 years of combined experience, I²r is able to perform comprehensive field analysis, site recommendations and design modification services. Our goal is to provide the best value product that is application specific to achieve maximum survivability.

NON-CONDUCTIVE HOSE
TECHNICAL SPECIFICATIONSview specs
Hi-Voltage Non-Conductive Hose
Non-conductive hose is used in applications where complete electrical non-conductivity is a critical issue. Both the SBR (Styrene-Butadiene Rubber) and the cover are non-conductive material. This hose is suitable for severe ellectrical applications like Induction furnaces, power plants, and underground mining applications.
Construction: The tube is non-conductive synthetic rubber. The tube is reinforced with plies of polyester tire cord. The hose cover is green in color constucted with weather and abraison resistant rubber.
80 Durometer Hose Cover - Shore D Tested
Temperature Range: Up to + 180°F
Electrical resistivity: 100 gigaohms per ft. @ 1000 volts DC or better
Inside Diameter Outside Diameter Plies WP (PSI) WT,
Lbs / Ft.
1/2" 1 2 200 0.38
3/4" 1.25 2 200 0.51
1" 1.54 2 200 0.71
1-1/8" 1.72 2 200 0.86
1-1/4" 1.84 2 200 0.93
1-3/8" 1.97 2 200 1.01
1-1/2" 2.09 2 200 1.08
1-9/16" 2.16 2 200 1.13
1-5/8" 2.22 2 200 1.16
1-3/4" 2.36 2 200 1.33
1-13/16" 2.41 2 200 1.37
1-7/8" 2.48 2 200 1.41
2" 2.71 4 200 1.71
2-1/4" 2.99 4 200 2.11
2-3/8" 3.11 4 200 2.21
2-1/2" 3.23 4 200 2.31
3" 3.73 4 200 2.71
3-1/2" 4.23 4 200 3.11
4" 4.73 4 200 3.52

INDUCTION HEATING WATER-COOLED
TECHNICAL SPECIFICATIONSview specs
Cable Size MCM
(mm²)
RDC @ 20°C
micro-ohms/ft.
Rac/Rdc RATIO
60HZ 1 Khz 3 Khz 10 Khz
133 (65.5) 77.97 1.001 1.281 2.04 3.485
266 (133) 38.98 1.005 1.708 2.768 4.826
350 (175) 29.63 1.009 1.924 3.126 5.481
400 (200) 25.92 1.012 2.044 3.327 5.844
500 (250) 20.74 1.018 2.25 3.686 6.515
532 (266) 19.49 1.021 2.31 3.791 6.704
600 (300) 17.28 1.026 2.439 4.014 7.105
750 (375) 13.83 1.04 2.687 4.447 7.9
798 (399) 12.99 1.04 2.764 4.767 8.368
1000 (500) 10.37 1.04 2.884 5.1 9.093
1064 (532) 9.75 1.08 3.033 5.261 9.391
1200 (600) 8.64 1.101 3.351 5.604 10.023
Quality + Innovation + Cost = VALUE

Induction Heating Cables

PRODUCT RENDERING